AXIS 292 - Maintenance
Follow the instructions below to reinstate the product factory default settings using the
Control button:
1. Switch off the AXIS 292 by disconnecting the power supply.
2. Press and hold the Control button pressed, and reconnect the power.
3. Keep the Control button pressed until the Status Indicator displays steady amber
(note that this may take up to 15 seconds), then release the button. When the
Status Indicator displays green (which can take up to several minutes) the AXIS
292 will then have been reset to its original factory default settings.
Upgrade Server
New firmware can be simply loaded into the AXIS 292 over the network. The latest version
of the AXIS 292 firmware is available free of charge from the Axis Web site at
http://www.axis.com/techsup or from your local distributor.
Note: Preconfigured and customized settings will be retained for use when the new firmware is running (provid-
ing that the features are available in the new firmware) although this is not guaranteed by Axis Communi-
cations. Always read the upgrade instructions and release notes available with each new release, before
updating the firmware.
1. Get the latest version of the firmware file either from the Axis Web site or from
your local distributor.
2. Save the firmware file to your computer.
3. Go to Maintenance in the network video decoder’s Web pages.
4. In the Upgrade Server section, browse to the downloaded firmware file on your
computer. Click Upgrade. The procedure can last for up to 20 minutes.
5. The AXIS 292 restarts automatically after the upgrade has completed.