AXIS P33 Series
Unit connectors
Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet. Using shielded cables is recommended.
Audio in - 3.5mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).
Audio out - Audio output (line level) that can be connected to a public address (PA) system or an active speaker with a
built-in amplifier. A pair of headphones can also be attached. A stereo connector must be used for the audio out.
SDHC memory card slot - The high capacity SD memory card can be used for local recording with removable storage.
I/O terminal connector - Used in applications for e.g. motion detection, event triggering, time lapse
recording and alarm notifications. It provides the interface to:
1 transistor output - For connecting external devices such as relays and LEDs. Connected
devices can be activated by the VAPIX Application Programming Interface (API), by the out-
put buttons on the Live View page or by an Event Type. The output will show as active
(shown under Event Configuration > Port Status) if the alarm device is activated.
1 digital input - An alarm input for connecting devices that can toggle between an open and closed circuit, for
example: PIRs, door/window contacts, and glass break detectors. When a signal is received the state changes and
the input becomes active (shown under Event Configuration > Port Status).
Auxiliary power and GND
The following connection diagram gives an example of how to connect an auxiliary device.
Function Pin Notes Specifications
GND 1 Ground
3.3V DC
Power
2 Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Max. load = 50mA
Digital
Input
3 Connect to GND to activate, or leave floating (or
unconnected) to deactivate.
Min. input= - 40V DC
Max. input= + 40V DC
Digital
Output
4 Uses an open-drain NFET transistor with the source
connected to GND. If used with an external relay, a
diode must be connected in parallel with the load,
for protection against voltage transients.
Max. load = 100mA
Max voltage = + 40V DC
Pin1
Pin2
Pin3
Pin4
1
2
E.g. push button
3
4
3.3V
max. 50mA
D
S
G